DL200D Professional Data Logger - Calibrated according to DAkkS D.2101

Product number KIT0002314
You save: 90.65 £
£606.96 £516.31 incl. VAT

show net price

Delivery status: Currently not available
Professional data logger DL200D

As well as environmental data about air temperature and humidity, the DL200D’s built-in sensors also detect current air pressure values.

The DL200H for tamper-proof measured value monitoring, recording and documentation of environmental data.
As well as environment data about air temperature and humidity, the DL200D's built-in sensors also detect current air pressure values.

Thanks to its flexible combination of real time data display, long term detection and logging of all measured values, even in network mode, the DL200D is the perfect measured data collector and an essential accessory for all precision measurements. Especially for calibration and testing laboratories.

A few practical benefits oft he DL200D:

  • Maintenance free made-in-Germany quality measuring devices
  • Tamper-proof measured value ­detection and documentation
  • Perfect for measuring over a long period
  • Simultaneous recording of up to 20 separate measuring channels
  • Network function (LAN)
  • Low energy consumption
  • Flexible power supply via batteries or USB – or optionally with PoE, also via LAN
  • Timer function, variable measured ­intervals, alarm function for each measuring channel
  • Three row LCD for displaying measured values
  • Including pro software
*DAkkS Calibration D.2101 for humidity and air temperature (%/°C)3 standard points are calibrated: 20%, 50%, 80%, each at a temperature of 20°C

Technical Data:

Internal sensor (temperature)
  • Principle: NTC
  • Measuring range: -20 °C to +50 °C
  • Accuracy: ±0.3 °C (0...40 °C), otherwise 0.5 °C
  • Display resolution: 0.1 °C


Internal sensor (humidity)
  • Principle: capacitive
  • Measuring: range: 10 to 95 % RH
  • Accuracy ±2 % RH
  • Display resolution: 0.5 °C RH


Internal sensor (air pressure)
  • Measuring range: 300 to 1.300 hPa abs.
  • Accuracy: ± 0,5 hPa
  • Display resolution: 0,1 hPa


Memory organisation
  • Data memory: integrated flash memory with 16 MB memory capacity (approx. 3,200,000 measuring values)
  • Data logging: up to 20 measuring channels parallel


Features and dimensions
  • LCD display: W 90 x H 64 mm
  • Housing: synthetic material
  • Dimensions: L 166 x W 32 x H 78 mm
  • Weight: approx. 250 g
  • Interfaces: USB, LAN
  • Connections for ext. measured value sensors: 2x 3.5 mm plug socket (sensors) and 2x BNC connector (electrodes)


Power supply
  • 4 x LR6 AA batteries
  • External power supply via USB


Scope of delivery:

Data logger, CD ROM with PC software for graphic and numerical representation of the assessment of the measured values, operating instructions, USB connecting cable, batteries

Optional: measuring device in PoE configuration, BUS sensors, ­extension cable
Technical data
General information
  Article number 3.510.260.040
Air temperature [°C]
  Measuring principle NTC
  Min. measuring range [°C] -20
  Max. measuring range [°C] 50
  Accuracy ± [°C] 0.3
  Display resolution [°C] 0.1
Relative humidity
  Measuring principle Capacitive
  Min. measuring range [% RH] 10
  Max. measuring range [% RH] 100
  Accuracy ± [% RH] 2
  Display resolution [% RH] 0.5
Air pressure
  measuring principle
  Measuring range [hPa] 300 – 1,300 (absolute air pressure)
  Accuracy ± [hPa] 0.5
  Display resolution [hPa] 0.1
CO₂ concentration
  Measuring principle
  Measuring range [ppm]
  Display resolution [ppm]
  Accuracy
  Long-term stability [ppm/a]
Thermal element K
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy Between -200 °C ... 0 °C [°C]
  Accuracy Between -200 °C ... 0 °C [°C] - Of measured value
  Accuracy Between 0 °C ... 1,200 °C [°C]
  Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value
  Resolution [°C]
Thermal element J
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy -200 °C ... 0 °C [°C]
  Accuracy -200 °C ... 0 °C [°C] - Of measured value
  Accuracy Accuracy between 0 °C ... 1,200 °C [°C]
  Accuracy Accuracy between 0 °C ... 1,200 °C [°C] - Of measured value
  Resolution [°C]
Thermal element S
  Min. measuring range [°C]
  Max. measuring range [°C]
  Accuracy Between -50 °C ... 0 °C [°C]
  Accuracy Between -50 °C ... 0 °C [°C] - Of measured value
  Accuracy 0 °C ... 1,700 °C [°C]
  Accuracy 0 °C ... 1,700 °C [°C] - Of measured value
  Resolution [°C]
PT100
  Min measuring range [°C]
  Max. measuring range [°C]
  Accuracy [°C]
  Accuracy of the measured value ± [%]
  Resolution [°C]
Voltage input
  Min. measuring range [V]
  Max. measuring range [V]
  Accuracy ± [µV]
  Accuracy of the measured value - Voltage input ± [%]
  Resolution
Current measurement
  Min. measuring range in two-wire operation [mA]
  Max. measuring range in two-wire operation [mA]
  Min. measuring range in three-wire operation [mA]
  Max. measuring range in three-wire operation [mA]
  Accuracy ± [µA]
  Accuracy of the measured value ± [%]
  Resolution [µA]
  Approx. output load [Ω]
Display
  LCD
  Size [mm] 90 x 64
Memory organisation
  Sensing interval 10/30s, 1/10/12/15/30 min, 1/3/6/12/24h
  Saving interval 1/10/12/15/30, 1/3/6/12/24 h
  Memory 16 MB, 3,200,000 measured values
  Data logging Up to 20 measurement channels in parallel
  Available measurement channels 32
  Available channel groups 8
  Software TR, DE, EN, ES, FR
Interface
  LAN
  USB
  Plug socket
  BNC
  RS-485
  10-pin terminal
Housing design
  Plastic
Power supply
  Internal (battery) 4 x 1.5 V AA, operating time > 1 year (depending on sensor and configuration)
  External (USB)
  External (LAN, PoE model)
  Terminals for external power supply to supply the sensor
Dimensions
  Length (packaging excluded) [mm] 166
  Width (packaging excluded) [mm] 32
  Height (packaging excluded) [mm] 78
Weight
  (packaging excluded) [kg] 0.25
Standard scope of delivery
Standard scope of delivery
  Measuring device
  Battery(-ies)
  USB connection cable
  CD-ROM with Smartgraph PC software and operating manual
Ascertainable measured values and functions
Internal sensors
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Relative air pressure [hPa]
  Absolute air pressure [hPa]
  CO₂ concentration [ppm]
External sensors
  CO₂ concentration [ppm]
  Surface temperature [°C]
  Surface temperature [°F]
  Material temperature [°C]
  Material temperature [°F]
  Air temperature [°C]
  Air temperature [°F]
  Wood moisture [digits]
  Building moisture [digits]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Battery voltage [mV, V]
  Voltage [mV, V]
  Current [mA, A]
  Absolute air pressure [hPa, Pa]
  Relative air pressure [hPa, Pa]
  Differential pressure [Pa]
  Flow rate [m/s]
  Mixing ratio [g/kg dry air]
  Particle concentration [0.1 µm]
  Particle concentration [0.2 µm]
  Particle concentration [0.3 µm]
  Particle concentration [0.5 µm]
  Particle concentration [1 µm]
  Particle concentration [5]
  Particle concentration [10]
  Particle concentration [x µm]
  Particle concentration [y µm]
  Particle concentration [z µm]
  Unknown
  Inactive
  Wet-bulb temperature [°C]
  Wet-bulb temperature [°F]
  Global radiation [W/m²]
  Daylight
  Amount of precipitation [l/m²]
  Wind speed [m/s]
  Wind direction
  Ground dampness
  Leaf wetness

 standard equipment

 optionally available

 not available

 

Hotline:

0 0800 80908090

Mon - Thu: 8:00am – 5:30pm

Friday: 8:00am - 5:00pm (CET)

E-Mail:

online-uk@trotec.com