Current and Temperature Measurement Package

Product number KIT0000408
You save: 31.63 £
£122.24 £90.61 incl. VAT

show net price

This package includes the professional clamp meter BE40 which helps you carry out indirect measurements of electrical current and the pyrometer BP20 for the easy and fast determination of surface temperatures.
BP20 Infrared Thermometer / Pyrometer

Power up the new BP20 and the multi-purpose, user-friendly, handheld measuring tool is ready to provide you with precise and reliable measuring results in a mere matter of seconds. The BP20 can quickly and reliably measure values between 35 °C and +800 °C and present them on a crisp and clear backlit display which make the models ideal for carrying out measurements in poorly-lit or pitch-black surroundings. And because the display is so easy to read, it can even offset the onset of fatigue! Now you can’t get much more user-friendly than that!

The BP20 infrared thermometer / pyrometer provides a bundle of benefits in practice:

  • Contact-free surface temperature measurements between -35 °C and +800 °C
  • Optical resolution 12:1
  • Sheer unbeatable value for money
  • Dual laser technology for measuring spot diameter display
  • Freely-selectable degree of emission from 0.1 to 1.0
  • Minimum/maximum value and hold function
  • Backlit display
  • Alarm





BE40 Clamp Meter

The BE40 is designed to allow you to carry out measurements quickly, comfortably and also extremely efficiently. The clamp meter registers the magnetic effect of the electric current, which means that the installation or the individual components conducting the electrical current do not have to be switched off while measuring is being carried out. The iron-core jaw clamps separate and are designed to go around cables, wires and conductor lines without coming into contact with them.

The fact that systems or facilities do not have to be shut down or switched off when the clamp meter is used means that the meter saves you both time and money by allowing inspections and checks to be carried out during normal operation without impacting on production or performance, thereby averting costly stoppages, service disruptions and other delays.

At-a-glance look at the BE40:

  • Measuring range electricity: 0.01 A AC - 1000 A AC
  • Measuring range voltage: 0 - 600 V (AC/DC)
  • Measuring range resistance: 0.01 Ω - 20 MΩ
  • Large, backlit display (3 3/4-lined)
  • Line diameter / jaw opening: approx. 30 mm
  • Diode test: Test current 0.3 mA, test voltage 1.5 VDC
  • Continuous peep: below threshold <120 Ω, test current <1 mA
  • Value falls short or exceeds measuring range threshold: “OL” appears in display
  • Measuring rate: 2 measurements/sec
  • Input impedance: 7.8 MΩ (VDC and VAC)
  • AC current band width: 50/60Hz (AAC)
  • AC voltage band width: 50/60Hz (VAC)
  • Surrounding temperature (operational): -10°C to 50°C (14°F to 122°F)
  • Surrounding temperature (storage): -30°C to 60°C (-22°F to 140°F)
  • Relative humidity: 0% ~ max. 85%
  • Measuring circuit category / Norm: CAT III 600V / IEC 61010
  • Micro-environment: Degree of soiling 2
  • Battery type: 2 x 1.5V AAA
  • Auto power off: after 15 mins of non-use
  • Dimensions: 229 x 80 x 48 mm
  • Weight: 303 g
  • Technical data
    General information
      Article number 3.510.003.031
    Optics
      Optical resolution (D:S) 12:1
      Smallest measuring spot Ø 12.5 mm (Distance 150 mm)
    Infrared temperature sensor [°C]
      Min. measuring range [°C] -35
      Max. measuring range [°C] 800
      Max. accuracy [°C] ±2 °C or ±2 % of measured value
      Accuracy < -4°C
      Accuracy -4°C to 65 °C
      Accuracy > 65 °C
      Accuracy < 20 °C
      Accuracy = 20 °C
      Accuracy -50 °C to 20 °C (-58 °F to 68 °F)
      Accuracy 21 °C to 300 °C
      Accuracy 301 °C to 1,000 °C
      Accuracy 21 °C to 400 °C
      Accuracy 401 °C to 800 °C
      Accuracy 800 °C to 1,600 °C
      Repeatability -50 °C to 20 °C
      Repeatability 21 °C to 1,000 °C
      Repeatability 21 °C to 1,200 °C
      Repeatability 1,201 °C to 1,600 °C
      Accuracy 20 °C to 500 °C (68 °F to 932 °F)
      Accuracy 500 °C to 1,000 °C (932 °F to 1,832 °F)
      Accuracy 1,000 °C to 1,850 °C (1832 °F to 3,362 °F)
      Repeatability 20 °C to 1,000 °C (68 °F to 1,832 °F)
      Repeatability 1,000 °C to 1,850 °C (1832 °F to 3,362 °F)
    Infrared temperature sensor [°F]
      Min. measuring range [°F] -31
      Max. measuring range [°F] 1,472
      Accuracy Min. [%] 1.5
      Accuracy ± Min. [°F] 4.5
      Accuracy Max. [%] 1
      Accuracy ± Max. [°F] 1.8
    Integrated temperature probe [°C]
      Min. measuring range [°C]
      Max. measuring range [°C]
      Accuracy ± Min. [°C]
      Accuracy ± Max. [°C]
      Accuracy ± 0 °C to 200 °C (32 °F to 392 °F) [°C]
      Accuracy ± =0 °C [°C]
    Integrated temperature probe [°F]
      Min. measuring range [°F]
      Max. measuring range [°F]
      Accuracy ± < 23 °F to 150 °F [°F]
      Accuracy ± > 150 °F [°F]
    Dew point temperature [°C]
      Min. measuring range [°C]
      Max. measuring range [°C]
      Accuracy
    Humidity
      Min. measuring range [%]
      Max. measuring range [%]
      Accuracy [%]
    Surrounding conditions
      Operation - min. temperature [°C] 0
      Operation - max. temperature [°C] 50
      Operation – min. relative humidity [% RH] 10
      Operation approx. - max. relative humidity (non-condensing) [%] 90
      Storage - min. temperature [°C] -10
      Storage - max. temperature [°C] 60
      Storage - max. relative humidity (non-condensing) [%] 80
    Display
      LCD
      Monochrome
    Interfaces
      USB
      Plug connection for type K temperature sensor
    Memory organisation
      Internal flash memory
    Device control
      Push buttons
      Membrane keyboard
    Type of protection
      IP54
      IP65
    Temperature sensor
      Response time 0.3 s
      Spectral sensitivity 8 - 14 µm
    Laser (target display)
      Class 2 (II)
      Wavelength [nm] 630 ~ 670
      Power [mW] 1
    Power supply
      Internal (battery) 1 x 9 V block battery
      Internal (battery)
      External (USB)
    Housing design
      Plastic
    Dimensions
      Length (packaging excluded) [mm] 150
      Width (packaging excluded) [mm] 45
      Height (packaging excluded) [mm] 108
    Weight
      (packaging excluded) [kg] 0.177
    Standard scope of delivery
    Standard scope of delivery
      Measuring device
      Battery(-ies)
      Bag/Holster
      Operating manual
      Contact temperature sensor type K
      Carrying case
      USB cable
      Mini tripod
    Ascertainable measured values and functions
    Functions and features
      Material temperature [°F]
      Material temperature [°C]
      Air temperature [°C]
      Air temperature [°F]
      Relative humidity [%]
      Dew point temperature [°C]
      Dew point temperature [°F]
    Internal sensors
      Minimum value display
      Maximum value display
      Hold function
      Switching function °C/°F
      Automatic switch-off
      Backlit display
      Selectable dual laser
      Alarm function with user-defined limit values
      Acoustic alarm function
      Non-stop measuring function
      Differential value display
      HACCP quick indicator LED
      Maximum value indication
      Open targeting sights
      Additional temperature measurement using external type K sensor
      Additional material temperature measurement using integrated type K insertion sensor
      Applicable for software-supported recording of measurement series
      Tripod thread connection
      Meets the specifications of the LFGB, §31 (German Food and Feed Code)
      Conforms with DIN 10955:2004
      Selectable single laser pointer
      Battery status indication
      Degree of emission fixed at 0.95
      Acoustic dew point alarm
      Visual dew point alarm
      Timer function
      Bar graph indicator for the quick identification of condensation risks
      Material temperature [°C]
      Material temperature [°F]

     standard equipment

     optionally available

     not available

    Technical data
    General information
      Article number 3.510.205.240
    DC voltage [V/DC]
      Min. measuring range [V] 0
      Max. measuring range [V] 600
      Accuracy ± [%] 0.8
    AC voltage [V/AC]
      Min. measuring range [V] 0
      Max. measuring range [V] 600
      Accuracy ± [%] 0.8
    Alternating current [A/AC]
      Min. measuring range [A] 0
      Max. measuring range [A] 1,000
      Accuracy ± [%] 3
      Max. diameter of conductor [mm] 30
    Resistance [Ω]
      Min. measuring range [Ω] 0
      Max. measuring range [Ω] 20 M
      Accuracy ± [%] 1
    Display
      LCD 3 3/4-digit
    Housing design
      Plastic
    Interfaces
      Connection sockets for 4 mm safety connectors (banana) 2 x
    Measuring circuit category
      CAT III (600 V)
    Safety
      EN 61.326
      EN 61010-1
      EN 61010-2-031
      Degree of pollution 2
    Power supply
      Internal (battery)
    Surrounding conditions
      Operation - min. temperature [°C] -10
      Operation - max. temperature [°C] 50
    Dimensions
      Length (packaging excluded) [mm] 229
      Width (packaging excluded) [mm] 48
      Height (packaging excluded) [mm] 80
    Weight
      (packaging excluded) [kg] 0.303
    Standard scope of delivery
    Standard scope of delivery
      Measuring device
      Battery(-ies)
      Bag/Holster
      Safety measuring lines with test probes
      Operating manual
      Contact temperature sensor type K
    Ascertainable measured values and functions
    Internal sensors
      AC voltage [V/AC]
      DC voltage [V/DC]
      Resistance [Ω]
      Alternating current [A/AC]
    External sensors
      Temperature [°C]
    Functions and features
      Maximum value display
      Hold function
      Automatic measuring range selection
      Measurement of alternating current, DC voltage, AC voltage, Resistance
      Automatic switch-off
      Backlit display
      Diode test
      Continuity check

     standard equipment

     optionally available

     not available

 

Hotline:

0 0800 80908090

Mon - Thu: 8:00am – 5:30pm

Friday: 8:00am - 5:00pm (CET)

E-Mail:

online-uk@trotec.com