T3000 Anemometer Set

Product number KIT0001498
£733.69 incl. VAT

show net price

T3000 Anemometer Set

With the T3000 from the MultiMeasure Professional series you are equipped ideally for different measuring purposes because you can connect almost all sensors and electrodes to this model from the well-known MultiMeasure program.
Professional Multifunctional measuring instrument to measure:

  • relative humidity and temperature
  • Surface temperature
  • Wood and building moisture
  • graphic display of moisture content distribution (raster measurement) as part of leak detection and damage location
  • Airflow
  • Trace gas (H2) as part of leak detection


Due to the innovative concept of a universal base unit with a novel button-touchscreen-control which can be completed with flexibly interchangeable sensors the operator doesn’t have to carry a whole collection of measuring instruments anymore. Through the extensive sensor and electrode range the measuring instrument T3000 is suitable for classic applications in industrial and laboratory measurement technology as well as for measuring in the construction diagnostics and many other areas of the building trade like heating/air conditioning/ventilation/sanitary provisions, flooring experts, coating companies, painters and carpenters which, for example, have to check moisture in walls, floors or wood.

Technical Data of the T3000:

Working area
  • Operating temperature: 0°C … +50°C
  • relative humidity: < 90% or. < 20g/m³ (non-condensing)
  • Altitude above sea level (NN): max. 3,000m


Storage
  • relative humidity: < 95% (non-condensing)
  • Ambient temperature: -20°C … +60°C


Compatibility SDI sensors (digital):
  • Air temperature and humidity
  • Material moisture
  • Airflow
  • H2 trace gas detection


Compatibility BNC electrodes:
  • Material moisture (building materials and wood) using the resistance measuring method


Energy & other
  • Memory for about 200 measurements consisting of maximum 3 x 3,600 measured values*
  • Dimensions (L x W x H): 170 x 62 x 34 mm
  • Battery: 4 pieces alkaline LR6 AA, 1,5V
  • optional energy supply: 5 V USB
  • Power consumption, active: ca. 400 mW
  • Battery durability, passive: ca. 1 year
  • Battery durability, active: minimum 24h
  • Real time clock with a programmed calendar until 2099


Advantages of the T3000 compared to its predecessor model T2000:

  • has all functions of the T2000 plus additional useful analysis functions
  • integrated memory
  • further, specialized menu functions
  • integrated logger function
  • more effective evaluation possibilities on the device itself(e.g. raster measurement)
  • Display made of high scratch-resistant glass with a modern, novel button-touchscreen-control
  • all old sensors, except fort he PT100, can be used further on
  • Especially developed evaluation software MultiMeasure Studio Standard and Professional (optional)
  • Software and device firmware update automatically


T3000 scope of supply:

  • 1x T3000
  • 1x USB connection cable
  • 4 x Batteries Alkaline LR6 AA, 1,5 V
  • 1 x display protection foil
  • Quick start guide (with reference to a download link to download the complete user manual)
  • Works test certificate
  • MultiMeasure Studio analysis software (standard version) to download (optionally available: professional version!)


* for ca. 200 measurement projects consisting of maximum 3 x 3,600 (=10,800) measured values, that is a total of 200 x 10800 (=2,160,000) measured values




TS 470 SDI Anemometer Sensor

With the TS 470 SDI sensor airflow speed and temperature are measured simultaneously. Minimum, maximum, average and “hold” values can be displayed optionally in addition to the measured value.

The technical data at a glance:

Sensor display 1: air velocity

  • Measuring range: 0.00 to 20.00 m/s
  • Resolution: 0.01 m/s
  • Accuracy: (± 0.2 m/s + 3% of the measured value)
  • Units: m/s, m³/s, m³/min, m³/h, l/min


Sensor display 2: air temperature

  • Measuring range: 0 °C to +50 °C
  • Resolution: 0.1 °C
  • Accuracy: ± 1.0 °C (at v > 0.5 m/s)
  • Units (Unit 2) for display sensor: °C, °F


Sensor element

  • Material: polycarbonate
  • Length / Ø: 200 mm / 12 mm
  • Sensor handle environmental conditions: 0 °C to +50 °C


The TS 470 SDI is being connected via a TC 30 connecting cable!

The anemometer sensor TS 470 SDI is not only suitable for finding weakpoints for certifying the air tightness of buildings (Blower Door) but also for checking the distribution of flow and temperature in ventilation and air conditioning systems.

Reconstruction companies also use it to check the capacity of their drying installations in insulation layer drying because this sensor allows them to determine quickly and exactly whether there is sufficient flow of air at the relief openings to dry out the insulation layer!




TC 30 Connecting Cable, SDI Sensors

For connecting and using SDI sensors to measure the temperature and moisture in different materials as well as to measure the relative humidity and air flow rates and to detect trace gas together with the T 2000 multifunction measuring device.

Technical data
General information
  Article number 3.510.200.027

 standard equipment

 optionally available

 not available

Technical data
General information
  Article number 3.510.200.220

 standard equipment

 optionally available

 not available

Technical data
General information
  Article number 3.510.207.010
Display
  TFT
  Colour
  Touch
Memory organisation
  Memory Integrated memory for approx. 200 measurements consisting of 3 x 3,600 measured values maximum
  Recording period 5, 10, 30, 60 min
  Storage type Internal flash memory
Interfaces
  USB
  BNC
  SDI
Device control
  Touch
  Cross control
Housing design
  Plastic
Type of protection
  IP54
Operating time
  Passive approx. 1 year
  Active approx. 24 h
Power supply
  Internal (battery) 4 x 1.5 V, AA
  External (USB) 5 V USB
  Internal (battery)
  External (USB)
Surrounding conditions
  Operation - min. temperature [°C] 0
  Operation - max. temperature [°C] 50
  Operation – max. relative humidity (non-condensing) [%] 90
  Storage - min. temperature [°C] -20
  Storage - max. temperature [°C] 60
  Storage - max. relative humidity (non-condensing) [%] 95
  Height above sea level (SL) Max. 3000m
Dimensions
  Length (packaging excluded) [mm] 170
  Width (packaging excluded) [mm] 62
  Height (packaging excluded) [mm] 34
Weight
  (packaging excluded) [kg] 0.305
Standard scope of delivery
Standard scope of delivery
  Battery(-ies)
  USB cable
  Display protection film
  Short operating instructions
  Factory test certificate
  PC software MultiMeasure Studio Standard (available for download)
  Operating manual
Ascertainable measured values and functions
External sensors
  Material temperature [°C]
  Material temperature [°F]
  Air temperature [°C]
  Air temperature [°F]
  Relative humidity [%]
  Absolute humidity [g/m³]
  Dew point temperature [°C]
  Dew point temperature [°F]
  Mixing ratio [g/kg dry air]
  Air flow rate [m/s]
  Air volume flow [m³/s]
  Air volume flow [m³/min]
  Air volume flow [m³/h]
  Air volume flow [l/min]
  Material moisture building [digits]
  Material moisture building [M-%]
  Material moisture building [CM-%]
  Material moisture wood [%]
  Trace gas H2 [digits]
Functions and features
  Maximum value display
  Minimum value display
  Hold function
  Display illumination with brightness control
  Acoustic alarm function
  Data logger function
  Material selection for anhydrite screed
  Material selection for cement screed
  Material characteristics for hundreds of types of wood for wood moisture measurement
  Data archiving
  Display archive contents
  Language selection
  Time
  Integrated calendar for clear file identification
  Graphic grid measurement function
  Display made of highly scratch-resistant "Blanview" special glass
  Automatic switch-off

 standard equipment

 optionally available

 not available

Technical data
General information
  Article number 3.510.220.265
Air flow rate [m/s]
  Min. measuring range [m/s] 0
  Max. measuring range [m/s] 20
  Accuracy [%] 3
  Accuracy ± [m/s] 0.2
  Resolution [m/s] 0.01
  Measuring principle Hot film anemometer
Air temperature [°C]
  Min. measuring range [°C] 0
  Max. measuring range [°C] 50
  Resolution [°C] 0.1
  Accuracy +0.7 °C (v > 0.5 m/s)
Interfaces / plug design
  Plug design SDI connector
Dimensions of sensor element
  Length [mm] 200
  Diameter Ø [mm] 12
Material of sensor element
  Polycarbonate
  Aluminium
  Stainless steel
  Composite
  Other
Material of handle
  Material Plastic
  Plastic/metal
  Metal
Surrounding conditions (measuring electronics integrated in handle)
  Min. operating temperature [C] 0
  Max. operating temperature [C] 50
Ascertainable measured values and functions
Internal sensors
  Air temperature [°F]
  Air flow rate [m/s]
  Air temperature [°C]
  Air volume flow [l/min]
  Air volume flow [m³/h]
  Air volume flow [m³/min]
  Air volume flow [m³/s]
Functions and features
  Stainless steel probe
  Plastic probe

 standard equipment

 optionally available

 not available

 

Hotline:

0 0800 80908090

Mon - Thu: 8:00am – 5:30pm

Friday: 8:00am - 5:00pm (CET)

E-Mail:

online-uk@trotec.com